Parameter Description
The valid range is 50 to 300. The default is 120.
For more information on the Active Alarms table, see Viewing
Active Alarms on page 879.
Note:
For the parameter to take effect, a <device> reset is
required.
To clear the acActiveAlarmTableOverflow trap, you must
reset the device. The reset also deletes all the alarms in
the Active Alarms table.
[AlarmHistoryTableMaxSize] Defines the maximum number of rows in the Alarm History
table. The parameter can be controlled by the Config Global
Entry Limit MIB (located in the Notification Log MIB).
The valid range is 50 to 1000. The default is 500.
Note: For the parameter to take effect, a device reset is
required.
no-alarm-for-disabled-port
[NoAlarmForDisabledPort]
Enables the device to not send the SNMP trap
acBoardControllerFailureAlarm, which indicates a "disabled"
(non-configured) telephony port. A disabled port is one that is
not configured at all or that is configured but without a Trunk
Group ID (i.e., Trunk Group ID is 0), in the Trunk Group table.
[0] Disable = (Default) The device sends the SNMP trap
for non-configured ports.
[1] Enable = The device does not send the SNMP trap for
non-configured ports.
Note:
The parameter is applicable to all telephony (analog and
digital) port types.
The parameter is applicable only to the Gateway
application.
configure system > snmp settings >
engine-id
[SNMPEngineIDString]
Defines the SNMP engine ID for SNMPv2/SNMPv3 agents.
This is used fo
r authenticating a user attempting to access the
SNMP agent on the device.
The ID can be a string of up to 36 characters. The default is
00:00:00:00:00:00:00:00:00:00:00:00 (12 Hex octets
characters). The provided key must be set with 12 Hex values
delimited by a colon (":") in the format xx:xx:...:xx. For
example, 00:11:22:33:44:55:66:77:88:99:aa:bb
Note:
For the parameter to take effect, a device reset is required.
Before setting the parameter, all SNMPv3 users must be
deleted; otherwise, the parameter setting is ignored.
If the supplied key does not pass validation of the 12 Hex
values input or it is set with the default value, the engine
ID is generated according to RFC 3411.
SNMP Trap Destination Parameters (configure system > snmp trap destination)
Note: Up to five SNMP trap managers can be defined.
SNMP Manager
[SNMPManagerIsUsed_x]
Determines the validity of the parameters (IP address and
port number) of the corresponding SNMP Manager used to
receive SNMP traps.