Version 7.2 1241 Mediant 500L Gateway & E-SBC
User's Manual 69. Configuration Parameters Reference
Parameter Description
[7] 7 = 2.00 dB/sec
[8] 8 = 2.50 dB/sec
[9] 9 = 3.00 dB/sec
[10] 10 = 3.50 dB/sec
[11] 11 = 4.00 dB/sec
[12] 12 = 4.50 dB/sec
[13] 13 = 5.00 dB/sec
[14] 14 = 5.50 dB/sec
[15] 15 = 6.00 dB/sec
[16] 16 = 7.00 dB/sec
[17] 17 = 8.00 dB/sec
[18] 18 = 9.00 dB/sec
[19] 19 = 10.00 dB/sec
[20] 20 = 11.00 dB/sec
[21] 21 = 12.00 dB/sec
[22] 22 = 13.00 dB/sec
[23] 23 = 14.00 dB/sec
[24] 24 = 15.00 dB/sec
[25] 25 = 20.00 dB/sec
[26] 26 = 25.00 dB/sec
[27] 27 = 30.00 dB/sec
[28] 28 = 35.00 dB/sec
[29] 29 = 40.00 dB/sec
[30] 30 = 50.00 dB/sec
[31] 31 = 70.00 dB/sec
AGC Redirection
configure voip > media ipmedia >
agc-redirection
[AGCRedirection]
Determines the AGC direction.
[0] 0 = (Default) AGC works on signals from the TDM side.
[1] 1 = AGC works on signals from the IP side.
AGC Target Energy
configure voip > media ipmedia >
agc-target-energy
[AGCTargetEnergy]
Defines the signal energy value (dBm) that the AGC attempts
to attain.
The valid range is 0 to -63 dBm. The default is -19 dBm.
AGC Minimum Gain
configure voip > media ipmedia >
agc-min-gain
[AGCMinGain]
Defines the minimum gain (in dB) by the AGC when activated.
The range is 0 to -31. The default is -20.
Note: For the parameter to take effect, a device reset is
required.
AGC Maximum Gain
configure voip > media ipmedia >
agc-max-gain
[AGCMaxGain]
Defines the maximum gain (in dB) by the AGC when activated.
The range is 0 to 18. The default is 15.
Note: For the parameter to take effect, a device reset is
required.
Disable Fast Adaptation
configure voip > media ipmedia >
agc-disable-fast-adaptation
[AGCDisableFastAdaptation]
Enables the AGC Fast Adaptation mode.
[0] = Disable (default)
[1] = Enable
Note: For the parameter to take effect, a device reset is

Table of Contents