MAX Operation & Service Manual 167MAX Operation & Service Manual Section7:Troubleshooting167
“Cleaner Spray” test for the cleaner spray is used to verify the coverage and pressure. This test allows
the technician to visually see how well the cleaning spray is covering the lane during a cleaning run.
The process is performed in two passes of the lane machine. The rst pass of the machine will clean
approximately 25 feet of the bowling lane. The second pass sprays cleaner to the bowling lane as it
travels without interference of the duster and the squeegee assembly. Refer to
Figure7-14.
Figure7-14.CleanerSpray
1. Select “Cleaner Spray” by pressing the button.
2. Press the handle button to prepare the lane machine to run a lane.
3. “Put the lane machine on the lane” when instructed.
4. Press the handle button again to start the cleaning operation of the “Cleaner Spray” test.
5. Press the handle button when the machine returns to the foul line, this will start the cleaner
spray coverage test.
NOTE: DONOTallowcleanertocompletelydryonlanesurface.Aftertestiscompleteditwill
benecessarytocleanandreconditionthelanewiththeappropriateconditionerpattern.