MAX Operation & Service Manual 171MAX Operation & Service Manual Section7:Troubleshooting171
Replacing the conditioner tank
NOTE: Verifythattheinsideoftheconditionertankiscompletelydryincludingthestainless
stealtubingandtankttings.Moisturethatremainswillcausethecontamiationerrorifnot
thoroughlydry.Itisalsoimportanttochecktheconditionersupplytubingiscleanandclear.
CleanthetubingwithIPA99ifcontaminationisstillpresent.
1. Position the conditioner tank into the machine and connect the wires to the contamination
sensor and level sensor. Set the tank on the tank support below.
2. Fasten the 2 screws that mount the tank to the left-side frame using the 3/8” socket or wrench.
3. Fasten the frame support (next to the tank) with the 4 screws using the 3/8” socket or wrench.
4. Connect the conditioner supply, return, and vent tubing making sure they are inserted properly.
5. Replace the battery and fasten with the two battery clamps and 4 screws using the 1/8” Allen
wrench.
6. Connect the battery to the electronic enclosure and turn the machine on from the main power
switch.
7. Fill the conditioner tank with lane conditioner until the oil is to the bottom of the tank opening.
If the contamination is still present the system will generate the Oil Contamination message.
8. Turn on the Temperature Cycle Override to circulate the oil until air is purged from the system.