SECTION 4 - ELECTRICAL SYSTEM SERVICE
page 4-17
Perfect Termination
902013S
Emergency Release Lever
902013M1
9. Check crimp and seal for damage; re-terminate if
necessary.
10. Emergency release level (4) on crimping tool.
VENDOR CONNECTOR
PN
CONTACTS
PN
SEALS
PN
EXTRACTION
TOOLS PN
CRIMP TOOL
PN
PACKARD 10752 (5) 225123C1-18/20AWG (10) 225124C1 (20) 1964525C1 (1) 425267A1 (1)
PACKARD 245482C1 (5) 225123C1-18/20AWG (10)
225122C1-14AWG (10)
225124C1 (20)
412914A1 (10)
1964525C1 (1) 425267A1 (1)
PACKARD 245484C1 (5) 225123C1-18/20AWG (10) 225124C1 (20) 1964525C1 (1) 425267A1 (1)
PACKARD 245483C1 (5) 225120C1-18/20AWG (10)
225119C1-14AWG (10)
225120C1 (20)
412914A1 (10)
1964525C1 (1) 425267A1 (1)
PACKARD 245485C1 (5) 225120C1-18/20AWG (10) 225124C1 (20) 1964525C1(1) 425267A1 (1)
PACKARD 245716C1 (5) 225120C1-18/20AWG (10) 225124C1 (20) 1964525C1 (1) 425267A1(1)
PACKARD 872290R1 (5) 1120922C1-14AWG (10) N/R 12133 (1)
Connector and Contact Table for Packard Connectors
NOTE: (#) indicates the number of parts in the connector service kit.