Chapter 6 Service and Maintenance
344
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
PE <n>: CA
System Error
Set
No PowerVU
support
Cause: Selected
program cannot
be descrambled.
Remedy: Check
the Installation
and Configuration
Guide for
PowerVu
descrambling
support. Ensure
that the
appropriate CAM
is inserted and
that the PE CAM
slot is assigned
correctly.
CA System
present in the
currently
selected
channel cannot
be descrambled
due to no
PowerVu ISE
or CAM
support.
Minor
93000-93031
PE <n>: CA
System Error
Set
No Matching
CAM
Minor
93000-93031
PE <n>: CA
System Error
Clear
Fault cleared
Minor
93000-93031
IP FEC Failure
(D9854-I only)
Set
FEC Encoder
Failure : FEC
bypassed
Cause: FEC FPGA
malfunction.
Remedy: Reboot
the system if FEC
is needed,
otherwise the
system will
continue to
operate bypassing
FEC.
This fault is
raised when
the FEC
Encoder or the
FEC Decoder
Lockup is
detected.
Major
95000
IP FEC Failure
(D9854-I only)
Set
FEC Decoder
Failure : FEC
bypassed
Cause: FEC FPGA
malfunction.
Remedy: Reboot
the system if FEC
is needed,
otherwise the
system will
continue to
operate bypassing
FEC.
The FEC
Encoder or the
FEC Decoder
Lockup is
detected.
Major
95000
IP FEC Failure
(D9854-I only)
Clear
Fault Cleared
The fault is
cleared if the
FPGA recovers
from lockup.
Major
95000

Table of Contents

Other manuals for Cisco D9854

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854 and is the answer not in the manual?

Cisco D9854 Specifications

General IconGeneral
ModelD9854
CategoryReceiver
OutputASI, IP
DecodingMPEG-2
Conditional AccessBISS
Receiver TypeProfessional IRD
解密DVB-CSA, BISS, AES
Input Frequency Range950 MHz to 2150 MHz
Modulation FormatsQPSK, 8PSK
Symbol Rate1 to 45 Msps
Power Supply100-240 VAC, 50/60 Hz
Power Consumption40W (typical)
Operating Temperature0°C