345
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
ETH Stack
Filters (D9854-I
only)
Set
HW Error
Detected
Cause: Incoming
traffic causes ETH
Stack Filters to
malfunction.
Remedy: If the
hardware
supports stack
filters reset,
normal operations
continue.
Otherwise, the
unit will reboot.
This alarm is
triggered when
the ETH Stack
Filters
hardware
detects an
internal error.
Major
97000
ETH Stack
Filters (D9854-I
only)
Clear
Fault Cleared
The fault is
cleared when
the detected
hardware error
is resolved.
Major
97000
D/R in
Progress
Set
Disaster declared
Cause: One or
more of the
following is
detected: RF lock
loss, unstable RF
signal, and/or
transport loss (RF
locked, but no
transport stream
packet received)
Remedy: A valid
signal.
A disaster is
detected.
Major
970
D/R in
Progress
Reset
No disaster
Disaster
recovery
feature is
cleared with a
valid signal.
Major
970

Table of Contents

Other manuals for Cisco D9854

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854 and is the answer not in the manual?

Cisco D9854 Specifications

General IconGeneral
ModelD9854
CategoryReceiver
OutputASI, IP
DecodingMPEG-2
Conditional AccessBISS
Receiver TypeProfessional IRD
解密DVB-CSA, BISS, AES
Input Frequency Range950 MHz to 2150 MHz
Modulation FormatsQPSK, 8PSK
Symbol Rate1 to 45 Msps
Power Supply100-240 VAC, 50/60 Hz
Power Consumption40W (typical)
Operating Temperature0°C

Related product manuals