Page #389 background image
365
Warning
Message
Type
Message
Cause/Remedy
Description
ID
D/R No DRT
Received
Set
No DRT
Received
Cause: Did not receive
the Disaster Recovery
Table from the uplink.
Remedy: Ensure that a
valid Disaster Recovery
Table is received from
the uplink, or switch to
the Local profile. If you
switch to the local
profile, the warning
message may persist if
you switch back to
Uplink profile and
Disaster Recovery Table
is still not received.
Contact your PNC
uplink administrator.
The unit is not
receiving the Disaster
Recovery Table from
the uplink.
99330
D/R No DRT
Received
Clear
DRT Table
Received
The error is cleared
before disaster
recovery search path is
generated.
99330
D/R Invalid
Tuning
Set
Invalid Tuning
for Backup (list of
affected D/R
Backup
Transports)
Cause: Any of the
possible tuning
validation failure
reasons not described by
the other disaster
recovery tuning
validation related
warnings (such as, a
tuner hardware failure).
Remedy: Export the
diagnostics file
(Support > Service
Action) and contact
Cisco Services.
The disaster recovery
backup transport
failed tuning
validation due the
reasons that are
described in the
exported diagnostics
file (Support > Service
Actions). For more
information, see
Loading a Software
Version (on page 302).
99340
D/R Invalid
Tuning
Clear
warning cleared
The error is cleared
before re-validating
the tuning.
99340

Table of Contents

Other manuals for Cisco D9854

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854 and is the answer not in the manual?

Cisco D9854 Specifications

General IconGeneral
ModelD9854
CategoryReceiver
OutputASI, IP
DecodingMPEG-2
Conditional AccessBISS
Receiver TypeProfessional IRD
解密DVB-CSA, BISS, AES
Input Frequency Range950 MHz to 2150 MHz
Modulation FormatsQPSK, 8PSK
Symbol Rate1 to 45 Msps
Power Supply100-240 VAC, 50/60 Hz
Power Consumption40W (typical)
Operating Temperature0°C

Related product manuals