Chapter 6 Service and Maintenance
366
Warning
Message
Type
Message
Cause/Remedy
Description
ID
D/R Invalid L-
Band
Set
Invalid calculated
L-band frequency
for Backup (list of
affected D/R
Backup
Transports)
Cause: Calculation of the
L-Band frequency
cannot be completed
based on the existing RF
input and Backup
Transport tuning
parameters.
Remedy: Contact your
PNC uplink
administrator to check
the tuning parameters
and RF Input LO
frequencies for the
identified disaster
recovery backup
transports.
The disaster recovery
backup transport
failed tuning
validation due to L-
Band calculation.
99350
D/R Invalid L-
Band
Clear
cleared
The error is cleared
before re-validating
the tuning.
99350
D/R Value Out
of Range
Set
Tuning
parameter out of
range for Backup
(list of affected
DR Backup
Transports)
Cause: One or more
tuning parameter values
in one or more of the
Backup Transport is
outside of the expected
range.
Remedy: Contact your
PNC uplink
administrator to check
the tuning parameters
and RF Input settings for
identified disaster
recovery backup
transports.
The Disaster Recovery
Table received from
the uplink is invalid.
99360
D/R Value Out
of Range
Clear
cleared
The error is cleared
before re-validating
tuning.
99360

Table of Contents

Other manuals for Cisco D9854

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854 and is the answer not in the manual?

Cisco D9854 Specifications

General IconGeneral
ModelD9854
CategoryReceiver
OutputASI, IP
DecodingMPEG-2
Conditional AccessBISS
Receiver TypeProfessional IRD
解密DVB-CSA, BISS, AES
Input Frequency Range950 MHz to 2150 MHz
Modulation FormatsQPSK, 8PSK
Symbol Rate1 to 45 Msps
Power Supply100-240 VAC, 50/60 Hz
Power Consumption40W (typical)
Operating Temperature0°C