Chapter 6 Service and Maintenance
Alarm Messages
Boot Host APP Invalid Application software
cannot be read from
memory correctly due
to a hardware issue.
Clear alarms, reset unit,
and notify customer
support if the problem
persists.
Major
MPE alarm Data lost, transport
error
Transport error
indicator is set in the
transport stream.
Verify that the uplink is
in good condition.
Major None.
MPE alarm Data lost, CRC
error
CRC error detected in
MPE stream.
Verify that the uplink is
in good condition.
Major None.
MPE alarm Data lost, CC error CC error detected in
MPE stream.
Verify that the uplink is
in good condition.
Major None.
MPE alarm Data lost, buffer
overflow
Buffer overflow
detected in MPE stream.
Reduce MPE rate. Major None.
MPE alarm Data lost, bad
sections
Bad section data
detected in MPE stream,
due to original data or
overflow issue.
Verify uplink is in good
condition and/or reduce
MPE rate.
Major None.
MPE alarm Data lost, MPE
capacity exceeded
Bit rate controller
dropping data due to
CPU load limitations.
Reduce MPE rate. Major None.
MPE alarm MPE capacity is
reached.
Unit is busy processing
or handling other
services.
Reduce service load. Major None.
LEC
Timeout
LEC Table
Missing/timeout:
channels currently
unavailable
LEC table is missing or
not received due to the
LEC table missing in
the signal.
Verify that the uplink is
sending LEC tables.
Major LEC received
Alarm Set Message Cause Remedy Severity Clear Message