2201R Mobile Tester SCPI Reference Guide
Chapter 8 Configuration commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
101
:CONFigure:GSM:BER:COUNt
Syntax
:CONFigure:GSM:BER:COUNt <long1>
Parameters
long1 is a long integer number.
The minimum value for long1 is 2,000, the maximum value is 1,000,000. The default value for long1 is 10,000.
Description
This command sets the number of bits that are used for a BER measurement.
Query
The query form of this command returns the current setting. The string delivered back contains one long integer
number.
Example
:CONFigure:GSM:BER:COUNt 100000
:CONF:GSM:BER:COUN?
Value returned: "100000".
:CONFigure:GSM:BER:RTDelay
Syntax
:CONFigure:GSM:BER:RTDelay <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 30. The default value for int1 is 0.
Description
This command allows to predefine a round trip delay in order to achieve a fast synchronization.
Note: During BER testing, there is a delay between the reception of the first burst of a particular voice block at the
mobile and the transmission of the first burst of the same voice block (after decoding and coding) on the uplink. This
delay is called the round trip delay.
Query
The query form of this command returns the current setting. The string delivered back contains one integer.
Example
:CONFigure:GSM:BER:RTDelay 9
:CONF:GSM:BER:RTD?
Value returned: "9"