2201R Mobile Tester SCPI Reference Guide
Chapter 8 Configuration commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
134
:CONFigure:GPRS:MSTAtion:MSLot
Syntax
:CONFigure:GPRS:MSTAtion:MSLot <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 1, the maximum value is 4. The default value for int1 is 2.
Description
This command sets the number of UL time slots that the mobile under test is commanded to use during multislot
testing.
Query
The query form of this command returns the current setting. The string delivered back contains one integer.
Example
:CONFigure:GPRS:MSTAtion:MSLot 4
:CONF:GPRS:MSTA:MSL?
Value returned: "4".
:CONFigure:GPRS:MSTAtion:PSLots
Syntax
:CONFigure:GPRS:MSTAtion:PSLots <int1>, <int2>, <int3>, <int4>
Parameters
int1 to int4 are integer parameters.
The minimum value for each intx is -26, the maximum value is 39. The resolution of each intx is 2, the default value
for each intx is 5.
Description
Sets the uplink power level in the range of -23 ... +39 dBm (GSM900) or -26 ... +36 dBm (upper band). Applies to GPRS
synchronous mode.
Query
The query form of this command returns the current setting. The string delivered back contains four integers.
Example
:CONFigure:GPRS:MSTAtion:PSLots -10,-6,0,6
:CONF:GPRS:MSTA:PSL?
Value returned: "-10,-6,0,6".