2201R Mobile Tester SCPI Reference Guide
Chapter 8 Configuration commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
87
:CONFigure:COUPloss:NAME
Syntax
:CONFigure:COUPloss:NAME <string1>
Parameters
string1 is a string giving the complete file name (and directory) of the coupling loss file to be loaded.
The maximum length of string1 is 50 characters.
The default for string1 is "example.cpl".
Description
This command loads the coupling loss description file, specified with the command parameter. Please note that the
data contained in the file need to be activated (using the CONF:COUP:STAT ON command described above) before
the data contained in the file specified has any effect on the measurement results.
Query
The query form of this command returns the name of the currently loaded coupling loss description file. The string
delivered back contains the full file name.
Example
:CONFigure:COUPloss:NAME "m7389.cpl"
:CONF:COUP:NAME?
Value returned: "m7389.cpl"