2201R Mobile Tester SCPI Reference Guide
Chapter 5 System commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
60
:SYSTem:COMMunicate:SERB:TERMinator
Syntax
:SYSTem:COMMunicate:SERB:TERMinator <PredefExpr>
Parameters
PredefExpr can take on either of the following expressions: LF|CR|CRLF.
Description
The command defines the delimiter for SCPI control strings on the USB interface.
Query
Reads and returns the current setting of the terminator used on the USB interface.
Example
:SYST:COMM:SERB:TERM LF
:SYST:COMM:SERB:TERM?
Returns the following string: "LF"
:SYSTem:DATE
Syntax
:SYSTem:DATE <int1>,<int2>,<int3>
Parameters
intx are three integers.
The minimum value for int1 is 1998, the maximum is 2100. The default value is 1998.
The minimum value for int2 is 1, the maximum is 12. The default value is 1.
The minimum value for int3 is 1, the maximum is 31. The default value is 1.
Description
Sets the system date. This command uses the following format: yyyymmdd where
yyyy stands for the four digits of the year (int1),
mm gives the two digits of the current month (int2) and,
dd represents the day of the current month (int3).
Query
Reads and returns the current system date in a string, using the format explained above.
Example
:SYST:DATE 2014,7,6
Sets the system date to the 6th of July, 2014.