2201R Mobile Tester SCPI Reference Guide
Chapter 11 Fetch commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
288
EDGE commands
:FETCh:EGPRs:RFTX:GROup?
Syntax
:FETCh:EGPRs:RFTX:GROup?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
The query form of this command returns the latest measurement result values of the sequence of EGPRS RF TX
measurements as specified with the :CONF:EGPRs:MEAS:GRO:RFTX command and measured with the
:MEAS:EGPRs[:ARRay]:RFTX:GROup command. As soon as all measurements of the first sequence have been
completed, a string is delivered back, containing the related measurement result values, separated by commas. The
type of the measurement result values (i.e. floating point real numbers, integers or boolean numbers) depends on the
measurements specified. The order of the measurement result values within the string is as described below for the
:FETCh:EGPRs:RFTX:ALL command.
Example
:CONF:EGPR:MEAS:GRO:RFTX POW,ERMS
:MEAS:EGPR:RFTX:GRO
:FETC:EGPR:RFTX:GRO?
In this example, the group of measurements is defined by a power level measurement combined with a EVM RMS
phase error measurement. The string returned in this example is:
"4.53,9.98".