2201R Mobile Tester SCPI Reference Guide
Chapter 9 Call commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
178
:CALL:GSM:MSINfo:PCONtrol
Syntax
:CALL:GSM:MSINfo:PCONtrol
Parameters
There are no parameters.
Description
This query delivers back the power control level currently used by the mobile.
Query
There is only a query form of this command available. The query delivers back one integer.
Example
:CALL:GSM:MSINfo:PCONtrol?
The integer delivered back is: "16".
:CALL:GSM:MSINfo:EFRCapab
Syntax
:CALL:GSM:MSINfo:EFRCapab
Parameters
There are no parameters.
Description
This query delivers back a boolean number indicating whether the mobile is capable of using enhanced full rate TCHs
or not.
A 0 means that the mobile under test is not able to support enhanced full rate TCHs.
Query
There is only a query form of this command available. The query delivers back one boolean number.
Example
:CALL:GSM:MSINfo:EFRCapab?
The boolean number delivered back is: "1".