2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
261
:MEASure:EGPRs:ARR:RFTX:TEMP
Syntax
:MEASure:EGPRs:ARR:RFTX:TEMP <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Checks multiple times (set with the int1 parameter) if TX burst fits into the power/time template. To read out the
entire measurement results array, use the :FETCh:EGPRs:RFTX:TEMPlate command.
Note: The power/time template is user-definable. It can be set up using the :CALC:EGPRs:RFTX:TEMP commands.
Query
The query form of this command returns a string containing int1 boolean numbers. A 0 indicates no violation of the
PTT by the current burst, while a 1 signals PTT violation. The single measurement results are separated by commas.
Example
:MEAS:EGPRs:ARR:RFTX:TEMP 10
:FETC:EGPRs:RFTX:TEMP?
The check of the current burst against the PTT is performed ten times. The check results are stored internally and read
out by the FETC command. An example of the string returned is: "0,0,0,0,0,0,1,0,0,0", indicating that the seventh burst
checked violated the PTT.
:MEASure:EGPRs:ARRay:RFTX:PPEAk
Syntax
:MEASure:EGPRs:ARRay:RFTX:PPEAk <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Performs the measurement of the peak phase error for a specific number of times (set with the int1 parameter). To
read out the entire measurement results array, use the :FETCh:EGPRs:RFTX:PPEAk command.
Query
The query form of this command performs the measurement the specified number of times (int1 parameter). As soon
as all measurements have been completed, all measurement result values are returned in a string. The string delivered
back contains int1 floating point real numbers with the physical dimension of degrees.
The single measurement results are separated by commas.
Example
:MEASure:EGPRs:ARRay:RFTX:PPEAk? 5
The string returned is: "5.13,5.23,4.97,5.21,4.59".