EasyManuals Logo

COBHAM 2201R Reference Guide

COBHAM 2201R
295 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #232 background imageLoading...
Page #232 background image
2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
232
:MEASure:GPRS:ARRay:RFTX:GROup
Syntax
:MEASure:GPRS:ARRay:RFTX:GROup <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Performs the RF TX tests, specified with the :CONF:GPRS:MEAS:GRO:RFTX command for a specific number of times
(set with the int1 parameter). To read out the entire measurement results array, use the :FETCh:GPRS:RFTX:GROup
command.
Note: Please keep in mind that the start of a new RF TX test always terminates any preceding measurement of the
same type instantly.
Query
The query form of this command starts the sequence of RF TX measurements as specified with the
:CONF:MEAS:GRO:RFTX command for a specific number of times (set with the int1 parameter). As soon as all
measurements have been completed, a string is delivered back, containing the related measurement result values,
separated by commas. The type of the measurement result values (i.e. floating point real numbers, integers or
boolean numbers) depends on the measurements specified. The order of the measurement result values within the
string is as described below for the :MEAS:GPRS:CONT:RFTX:ALL command.
Note: Please keep in mind that the number of measurement results delivered back is the number of measurement
results of a single execution multiplied with the int1 parameter.
Example
:CONF:GPRS:MEAS:GRO:RFTX POW,PRMS
:MEASure:GPRS:ARRay:RFTX:GROup? 3
In this example, the group of measurements is defined by a power level measurement combined with a RMS phase
error measurement. This group of measurements is carried out three times. After all measurements have been
completed, a result string is delivered back, containing six measurement result values.
The string returned is:
"4.53,9.98,4.08,10.02,4.32,9.99".