2201R Mobile Tester SCPI Reference Guide
Chapter 2 Remote control of the 2201R Mobile Tester
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
38
SCPI command errors
This subsection contains a table of SCPI command errors.
NOTE
If a query for an error code returns “0” then no error did occur.
Error Code Meaning
100 Command error.
101 Invalid character.
102 Syntax error.
103 Invalid separator.
104 Data type error.
108 Parameter not allowed.
109 Parameter missing.
111 Header separator error.
112 Program mnemonic too long.
113 Undefined header.
114 Header suffix out of range.
121 Invalid character within a number.
123 Exponent too large.
128 Numeric data not allowed in this context.
131 Invalid suffix.
134 Suffix too long.
138 No suffix allowed in this context.
141 Invalid character data.
144 Character data too long.
145 ENUM data too long.
158 No string allowed in this context.
160 Block data error.
168 No block data allowed in this context.
200 General execution error.
201 Execfunc error.
202 Query function error.
221 Different parameter settings lead to a conflict.
222 Data out of range.