2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
189
Introduction
The MEASure subsystem is probably the most important SCPI command subsystem of the 2201R. There, you will
find all commands required to acquire measurement results of the mobile under test.
GSM commands
:MEASure:GSM[:CONTinuous]:RFTX:STOP
Syntax
:MEASure[:GSM][:CONTinuous]:RFTX:STOP
Parameters
There are no parameters.
Description
Stops a continuous measurement of the RF TX tests.
Note Stopping the test is not required since a test is automatically stopped when you start a new test.
Query
The query form of this command is not available.
Example
:CONF:GSM:MEAS:GRO:RFTX POW,PRMS
:MEAS:RFTX:GRO
:MEAS:RFTX:STOP
Configures, starts and stops a measurement.