Page #113 background imageLoading...
Page #113 background image
E-GENIUS
101
4
Barcode Configuration > Code Collection
When Code Collection has been selected from the Code Combination drop-down list, the
Barcode Configuration window reveals related input fields.
1. Enter the appropriate information in the form as described below:
Field Name
Action/Definition
Code Combination
Code Collection has been selected.
No Read Message
Select Disable No Read Message, Global No Read Message, or Local No
Read(s) Message from the drop-down list. The No Read condition occurs
whenever a code cannot be read or decoded.
Disable No Read Message: The No Read Message is not transmitted.
Global No Read Message: The No Read String will be sent if the
scanner is unable to decode one or more barcodes in the reading
phase.
Local No Read(s) Message: This option is useful when one or more
codes are not read in the reading phase or when more codes than the
expected number set by the configuration parameters are read.
If working in Standard Multi Label mode, this option activates the
Code Label Local No Read String and the Code Label Local
Multiple Read String parameters which allow setting a Local No Read
String and a Local Multiple string for each defined code symbology.
Use 'Global No Read
String' when No
Codes Read
Select the check box to allow the Global No Read String to be used if no codes
at all are read. This option is not available when Global No Read Message is
selected from the No Read Message drop-down list.