DS8110 REFERENCE MANUAL
134
4
Field Name
Action/Definition
NOTE: This option is only available when an Operating Mode of
On Line is selected in Modify Settings | Global Settings | Operating
Mode.
Termination
After No Read
Message
Select Enable or Disable from the drop-down list. If Enable is selected, a termination string
is added to the No Read message string.
NOTE: This option is only available when an Operating Mode of
On Line is selected in Modify Settings | Global Settings | Operating
Mode.
Format Type: Standard
Header String
Click to activate the Text Entry Tool and create a Header String in the text field
provided. Headers (up to 128 bytes) can be defined and transmitted as a block preceding
the barcode(s). Use characters from NUL (00H) to ~ (7EH).
Click Submit to save your text to the origin window text field, or click Cancel to return to
origin window without transferring text.
Termination
String
Click to activate the Text Entry Tool and create a Termination String in the text field
provided. Terminators (up to 128 bytes) can be defined and transmitted as a block
following the barcode(s). Use characters from NUL (00H) to ~ (7EH). Click Submit to
save your text to the origin window text field, or click Cancel to return to origin window
without transferring text.
Data Packet
Separators
Click to activate the Text Entry Tool and create a Data Packet Separators in the text
field provided. The Data Packet Separators (up to 128 bytes) are used to separate
barcodes in the reading phase. Use characters from NUL (00H) to ~ (7EH).
For this reason, it is very useful when the Standard Multi Label, Code Collection or
Code Combination parameters have been selected in the Barcode Configuration. If
selected, they occur within the Code Field and are transmitted after each decoded code.
Click Submit to save your text to the origin window text field, or click Cancel to return to
origin window without transferring text.
Code
Position Tx
Select the check box to enable. If enabled, the code position information is included in the
output data format.