EasyManua.ls Logo

Delphin ProfiMessage - Page 53

Delphin ProfiMessage
322 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProfiMessage
I/Omodules.AProfiMessagedevicecanbefittedwithtwoI/Omodules.TheCAN-
connectionisestablishedinternally.
TheDCPCANbusforI/Oextensionsusesthe"Ext.BUS"port.IfaProfiMessage
devicehasaninsufficientnumberortypeofinputchannels,aslavedevicecan
thenbeconnectedtotheProfiMessagedeviceviathisport.(RefertoDevicecon-
nections).
Connecting the extension bus
Usetwistedpairshieldedcable(e.g.braidedLiYCY2x0.14mm2TP).Ensurethat
thestartandendconnections(i.e.atthemasterandatthefinalslavedevice)use
thesupplied120-ohmresistors.Theseproducethebussignallevelandprevent
interferencefromsignalreflection.TheHi(CANHigh)designatedportsmustbe
connectedtootherdevicesviaHi,andLo(CANLow)withLo.
Illustration in DataService Configurator
TheChannels tabliststhemodulescurrentlyconnectedaccordingtothetypeof
viewselected(hardwarevieworuser-defined)inthegroup"Extension(CAN)
bus"grouporasI/Omodulesfromthe(master)device.
I/OmoduleconfigurationisexplainedinConfiguringmodulechannels.
Configuring the extension bus
TheextensionbusprotocolcannotbechangedandissettoDCP (DelphinCANPro-
tocol).
53
Delphin Technology AG
Dezember 2015
ProfiMessage Manual

Table of Contents