ProfiMessage
Controller type K TN TV
PID 0.4/(KI*Tu) 3.2*Tu 0.8*Tu
4.7.14.3 ConfiguringPIDcontrollers
ThecontrollerisspecificallyconfiguredintabsMainsettings”,Controller1”and
“Controller2”.
SettingsintabsController1”and“Controller2”areonlyrequiredforspecific
applications.
Thecontrollerchannelobtainsitsinputvalues(setpointvariableW”andprocess
variableX”fromtwoHWchannelsorSWchannelsofthedevice).Thecontroller
yieldsthemanipulatedvariable“Y”astheoutputvalueinthepresetvaluerange
0...100%or-100..+100%.Ifyoulinktheoutputofthecontrollerchanneldirectly
withananalogueoutput,youmustenterthesamescaling0...100%or-
100...+100%.