5 Applied Instructions and Basic Usage
Example 2
A radian/degree flag is set to ON. The value in (D1, D0) is a degree in the
range of 0° to 360°. When X0 is ON, the tangent of the value in (D1, D0) is
stored in (D11, D10). The value in (D11, D10) is a binary floating-point value.
Radian/Degree flag
M100
2
SET
X0
DTAN D0 D10
Tangent
Binary floating-point value
Degree
D 1 D 0
S
D
D 11
D 10
Additional
remark
Please refer to section 5.3 for more information about performing operations
on floating-point values.
DVP-20PM Application Manual
5-115