9 Electronic Cam
9.4.1.2 Measurin
g the Relation between the Position of a Master Axis and the Position of
a Slav
e Axis at Work
Users can store the relation between the positions of the master axis specified and the positions of the
slave axis specified in a file in the CAMData folder, and then import the relation into a cam chart in
PMSoft. The steps of importing the relation between the positions of the master axis specified and the
positions of the slave axis specified into a can chart in PMSoft are as follows.
1. Store data about displacement in Data_S.txt in the folder in the CAMData folder.
2. Open a CAM Chart window in PMSoft, and then type a value in the Resolution box.
DVP-20PM Application Manual
9-23