5 Applied Instructions and Basic Usage
DVP-20PM Application Manual
5-151
Name Type Value Motion control function block Description
IntX03 WORD 4 The source of an interrupt signal is X3.
IntX04 WORD 5 The source of an interrupt signal is X4.
IntX05 WORD 6 The source of an interrupt signal is X5.
IntX06 WORD 7 The source of an interrupt signal is X6.
IntX07 WORD 8 The source of an interrupt signal is X7.
IntStart0 WORD 1 The source of an interrupt signal is Start0.
IntStop0 WORD 2 The source of an interrupt signal is Stop0.
IntStart1 WORD 3 The source of an interrupt signal is Start1.
IntStop1 WORD 4
T_Interrupt
The source of an interrupt signal is Stop1.
mcCmpAxis1 WORD 0
The source of a comparison is the present
position of the first axis.
mcCmpAxis2 WORD 1
The source of a comparison is the present
position of the second axis.
mcCmpAxis3 WORD 2
The source of a comparison is the present
position of the third axis.
mcCmpAxis4 WORD 3
The source of a comparison is the present
position of the fourth axis.
mcCmpC200 WORD 4 The source of a comparison is the value of C200.
mcCmpC204 WORD 5 The source of a comparison is the value of C204.
mcCmpC208 WORD 6 The source of a comparison is the value of C208.
mcCmpC212 WORD 7
T_Compare
The source of a comparison is the value of C212.
mcCmpCLR0 WORD 0 The device used for a comparison is CLR0.
mcCmpCLR1 WORD 1 The device used for a comparison is CLR1.
mcCmpY0 WORD 0 The device used for a comparison is Y0.
mcCmpY1 WORD 1 The device used for a comparison is Y1.
mcCmpY2 WORD 2 The device used for a comparison is Y2.
mcCmpY3 WORD 3 The device used for a comparison is Y3.
mcCmpRstC200 WORD 4 The device used for a comparison is C200.
mcCmpRstC204 WORD 5 The device used for a comparison is C204.
mcCmpRstC208 WORD 6 The device used for a comparison is C208.
mcCmpRstC212 WORD 7
T_Compare
The device used for a comparison is C212.
mcCapAxis1 WORD 0
The source of capture is the present position of
the first axis.
mcCapAxis2 WORD 1
The source of capture is the present position of
the second axis.
mcCapAxis3 WORD 2
The source of capture is the present position of
the third axis.
mcCapAxis4 WORD 3
The source of capture is the present position of
the fourth axis.
mcCapC200 WORD 4 The source of capture is the value of C200.
mcCapC204 WORD 5 The source of capture is the value of C204.
mcCapC208 WORD 6 The source of capture is the value of C208.
mcCapC212 WORD 7
T_Capture
The source of capture is the value of C212.
mcCapPG0 WORD 0 The source of a capture signal is PG0.
mcCapMPGB0 WORD 1 The source of a capture signal is MPGB0.
mcCapMPGA0 WORD 2 The source of a capture signal is MPGA0.
McCapLSN0 WORD 3 The source of a capture signal is LSN0.
McCapLSP0 WORD 4 The source of a capture signal is LSP0.
McCapDOG0 WORD 5 The source of a capture signal is DOG0.
mcCapStop0 WORD 6 The source of a capture signal is Stop0.
mcCapStart0 WORD 7 The source of a capture signal is Start0.
mcCapPG1 WORD 8 The source of a capture signal is PG1.
mcCapMPGB1 WORD 9 The source of a capture signal is MPGB1.
mcCapMPGA1 WORD 10
T_Capture
The source of a capture signal is MPGA1.
mcCapLSN1 WORD 11 T_Capture The source of a capture signal is LSN1.