9 Electronic Cam
signals as input signals of Master).
(6) Set up lower bound of CAM sync output D1839, D1838=20000 and upper bound D1843,
D1842=30000. Between Master position 20000~30000 (can be monitored by D1862), CLR0
is ON. However, the CLR LED on the MPU will not respond to it. To monitor CLR signal,
users can connect CLR0- to 0V, connect CLR0+ to Xn input contact, connect S/S2 to 24V,
and then monitor the ON/OFF status of Xn input.
2. Set M0 to ON to enable cyclic electronic cam. When M0 is rising-edge triggered, Master starts
to receive the variable speed pulses from Y axis, and Slave operates according to the above
electronic cam data curve. In addition, CLR0=ON during Master position 20000~30000.
3. Reset M0.
Program
DMOV K5000 D1920
M1002
ZRST D1860 D1863
M1002
DMOV K20000 D1838
DMOV
K30000
D1842
MOV
H10 D1926
MOV H2000 D1846
ZRST D1848 D1849
Set up pulse input type
as A/B phase
Set up D1799 (input terminal polarity setting)= 6.
MPGA0/MPGB0 are NO contacts.
Set up operation speed of Y axis
variable speed operation
MOV H200 D1864
MOV H30 D1896
MOV K6 D1799
MOV H0 D1846
M0
M0
LD= D1846 H2000
Lower bound of E-CAM sync output
Upper bound of E-CAM sync output
When D1846=H2000, Y axis variable speed
operation executes.
When M0 is rising-edge triggered, set
D1846=H2000 to enable cyclic E-CAM
When M0 is falling-edge triggered, cyclic E-CAM
stops.
DVP-20PM Application Manual