9 Electronic Cam
Parameter Setting value
Distance for which the master axis specified moves 1000
Distance for which the slave axis specified moves 500
Distance for which the slave axis specified is
synchronized with the master axis specified
300
Synchronization ratio of the speed of the slave axis
specified to the speed of the master axis specified
1.0
Max magnification ratio 10.0
Acceleration curve 0
Cam curve 0
Cam curve setting
Only single data real-time
modification is applicable
Result 0
【
Steps】
1. Open a CAM Chart window in PMSoft, and then type 300 in the Resolution box.
2. Download the program created to a DVP-20PM series motion controller, and then execute the
program.
3. Set M1 to write the parameters into D100~D112 and K10000 into D0.
4. Set M0 to write the data in D0~D15 into the special register K10000. After M0 is set to ON, a
rotary cut curve will be created.
5. Stop the DVP-20PM series motion controller, and then upload the program in the DVP-20PM
series motion controller.
6. View the first curve in the CAM Chart-0 window. The curve is a rotary cut curve which is created
automatically.
DVP-20PM Application Manual
9-37