10 Application of G-codes
Step 6: PMGDL can download multiple G-code files to DVP20PM00M. Click Send and the file will
be downloaded to Ox0. Click Send Next, and the file will be downloaded to Oxn (n
increases 1 at a time). If only Ox0 is required, the step can be skipped.
P.S.: Next time when G-codes need to be updated, only steps after step 3 are required.
DNC mode
DNC mode is applied for G-code file with over 5000 rows of instructions. In DNC mode, O100 do
not need to be executed for calling Ox0 motion subroutine. When DNC mode is select by PMGDL, a
DVP-20PM series motion controller will automatically execute Ox0 when G-codes are downloaded
to the DVP-20PM series motion controller.
Step 1: The program downloaded to a DVP-20PM series motion controller should contain Ox0
motion subroutine, and G-codes do not need to be designed in Ox0. To create Ox0, click
OX in the system information area in PMSoft. Double click at 0 and the OX0 editing window
will pop up automatically. After Ox0 is created, follow step 1 of Common mode to set up
O100.
Step 2: Same as Step 2 of Common mode
Step 3: same as Step 3 of Common mode
Step 4: (1) Select the DNC mode checkbox. (2) Click Open to view the G-code file to be
downloaded. (3) Click Send to download the G-code file. Ox0 will automatically be enabled
if download is succeeded.
(A) Select the DNC mode checkbox.
(B) Click Open to view the G-code file to be
downloaded.
DVP-20PM Application Manual