11 CANopen Communication Card
CR#n90~CR#n91: Target position of an interpolation mode
[Description]
The control registers are used to set the target position of an interpolation mode.
Range: -2,147,483,648 ~2,147,483,647
Data type: Double word
CR#n92: Enabling an interpolation mode
[Description]
An interpolation mode will be executed if the value in the control register is 1. An interpolation mode will
be disabled if the value in the control register is 0.
CANopen common mode
CR#500: CANopen mode switch
[Description]
The control register is used to switch the CANopen mode of DVP-FPMC. If the value in the control
register is 1, the CANopen mode of DVP-FPMC is an A2 mode. If the value in the control register is 2, the
CANopen mode of DVP-FPMC is a normal mode.
Default value: 1
Control registers for an A2 mode will be unavailable if the CANopen mode of DVP-FPMC is a normal
mode. Control registers for a normal mode will be unavailable if the CANopen mode of DVP-FPMC is
an A2 mode.
CR#504: Enabling a heartbeat protocol
[Description]
If a heartbeat protocol is enabled in a common mode, the heartbeat mechanisms of node ID 1~nod ID
16 (slaves) will be enabled by a master. If the value in the control register is 0, a heartbeat protocol is
disabled. If the value in the control register is 1, a heartbeat protocol is enabled.
CR#505: Execution statuses of a heartbeat protocol
[Description]
The control register is used to display the execution statuses of the heartbeat protocol executed by
node ID 1~node ID 16. If the value in the control register is 0, the execution of a heartbeat protocol is
completed. If the value in the control register is 1, a heartbeat protocol is being executed.
CR#506: Heartbeat statuses
[Description]
The control register is used to display the heartbeat statuses of node ID1~node ID 16. Node ID 1~node
ID 16 correspond to bit 0~bit 15. If the heartbeat mechanism of a slave is enabled successfully, the bit
corresponding to the salve is 1. If the heartbeat mechanism of a slave is not enabled, the bit
corresponding to the salve is 0. In addition, if a slave is disconnected from a master, the bit
corresponding to the slave is 0.
1
23
4
012345678910111
2
1
3
141
5
5
6
7
8
9
1011
12
13141516
Bit
Heartbeat statuses of slaves
Node IDs
DVP-20PM Application Manual
11-15