S600+ Instruction Manual
7-6 Startup Revised July-2017
S600
ENTER NEW MODBUS
ADDRESS
(1...247)
CURRENT 00001
_
Figure 7-5. Modbus Screen
3. Enter the address value (any value between 1 and 247). If you
change the Modbus address, you must restart the S600+ in order
for the change to take place.
PC Comms
Note: If you are using an Ethernet connection, you do not need to
modify these settings.
To define the Modbus network addresses:
1. PC SETUP MODE
2. PC ALM/ACC MODE
3. PC BAUD
4. PC DATA
5. PC STOP
6. PC PARITY
7. GO BACK
Figure 7-6. Modbus Screen
Menu options include:
Option
Description
PC Setup Mode
Sets the byte count for PC communications. Valid
values are 8-bit and 16-bit.
PC ALM/ACC Mode
Sets the ACC alarm. Valid values are Enabled
and Disabled.
PC Baud
Sets port baud rate. Valid values are 2400 bps to
57600 bps.
PC Data
Sets the bit count. Valid values are 7 and 8.
PC Stop
Sets the stop bits. Valid values are 1 and 2.
PC Parity
Sets parity. Valid values are 0 (No), 1 (Odd), and
2 (Even).
Go Back
Returns to the Network Definition menu.

Table of Contents

Other manuals for Emerson FloBoss S600+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson FloBoss S600+ and is the answer not in the manual?

Emerson FloBoss S600+ Specifications

General IconGeneral
BrandEmerson
ModelFloBoss S600+
CategoryController
LanguageEnglish

Related product manuals