132 Chapter 11 Groups
Group Editing mode in Blind
Add or delete channels or change channel levels in a recorded group by
first entering Group Editing mode in Blind. You can also set group levels
with reference to a focus point.
59
59.
See Setting levels with focus points, page 150.
Keystrokes: Action:
1. Press [Blind]. Selects Blind display mode
2. Press [Group] [1]. Selects group 1’s channels
Prompt reads:
Group mode – To recall a group, select
the number and set it to a level
To create or modify a group, select
the number and press ENTER
3. Press [Enter]. Sets channels to their levels recorded in
the group
Prompt reads:
Select channel numbers
4. Press [2][5] [Thru] [3][0]
[At] [5][0].
Modifies look, adding channels 25
through 30 at 50 percent
5. Press [Record]. Prompt reads:
To record group, select number and
press ENTER
To cancel, press CLEAR
6. Press [Enter].
a
a. Specify a number here to record to a different group, such as
[5][0] [Enter]. If that group exists, it is overwritten. If it does not
exist, it is created.
Records the modified group