G5/G6-Family AT Commands User Manual Page
Parameter indicating the presence of any of the
optional parameters which follow.
Optional:
Protocol-Identifier. Values between 0-255.
Optional:
Data Coding Scheme. Values between 0-255.
Optional: User data length
Any unused bits will be set to zero by the sending entity and will be ignored by the receiving entity.
The maximum guaranteed length of TP-UD is 131 octets. In order to achieve the maximum octet of
143, the TP-RA field must have a length of two octets and TP-PID and TP-DCS must not be present.
TP-PI is Mandatory if any of the optional parameters following TP-PI is present, otherwise optional.
Mandatory:
Message-Type-Indicator
Parameter describing the message type.
1 0 SMS-STATUS-REPORT (in the direction SC to MS)
Mandatory:
TP-More-Message-To-Send
Parameter indicating whether or not more messages is
waiting to the MS in the SC.
0 More messages are waiting for the MS in this SC
1 No more messages are waiting for the MS in this SC
Mandatory:
TP-Status-Report-Qualifier
Parameter indicating whether the
previously submitted TPDU was an SMS-SUBMIT or an
SMS-COMMAND:
0 The SMS-STATUS-REPORT is the result of a
SMS-SUBMIT.
1 The SMS-STATUS-REPORT is the result of an
SMS-COMMAND
Optional:
TP-User-Data-Header-Indicat
or
Parameter indicating whether or not a status report will be
returned to the SME.
0 A status report will not be returned to the SME
1 A status report will be returned to the SME