G5/G6-Family AT Commands User Manual Page
26
of
243
ATS0=3
OK
ATS0?
003
OK
4.1.5 S12
This command handles the selection of the guard time, which is stored in S-Register 12, and specifies the
behavior of escape characters during ODM connection.
Note: For a guard time specified by S-Register 12, no character should be entered before or after "+++".
The duration between escape codes must be smaller than the guard time.
Command
Syntax
Response/Action
Remarks
Set
S12=<guard_tim
e>
OK
+CME ERROR:
<err>
The Set command sets the ODM
escape character guard time value if
all parameters are valid.
Read
S12?
<guard_time>
OK
The Read command displays the
current ODM escape character guard
time.
The following table shows the S12 parameters.
<Parameter>
Description
<guard_time>
ODM escape character guard time (units of 50 msec). Range is 0 to 255.
The default value is 50.
4.1.6 &V, View Configuration
This command reports the current S-registers.
Command
Syntax
Response/Action
Remarks
Execute
&V
ACTIVE PROFILE:
...
(profile data)
STORED PROFILE 0:
The Execute command displays the
current active configuration.