EasyManua.ls Logo

Fibocom G510 - 8.1.6 +CLCK, Facility Lock

Fibocom G510
243 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G5/G6-Family AT Commands User Manual Page
126
of
243
AT+CLCK="ai",2
+CLCK: 1,1
+CLCK: 1,2
+CLCK: 1,4
OK
AT+CPWD="ai","old password","new password"
OK
8.1.6 +CLCK, Facility Lock
This command locks, unlocks or interrogates a Module or a network facility <fac> (any kind of call barring
program). A password is mandatory for performing locking and unlocking actions, but not for querying.
The features of the Module that are affected by this are the keypad power-up operation and fixed dialing
list. When querying the status of a single call barring program <mode>=2, the <status> for each call type
will be returned.
For <fac>="SC", SIM Card PIN setting and for <fac>="FD", SIM Fixed Dialing memory setting, the
<class> is irrelevant (For more information about <class>, refer to the following table shows the +CLCK
parameters.). The <passwd> for "SC" is SIM PIN, and for "FD" it is SIM PIN2.
Command
Syntax
Response/Action
Remarks
Set
+CLCK=<fa
c>,<mode>[,
<passwd>[,
<classx>]]
For <fac> where <class> is
irrelevant(SC, FD):
+CLCK=<fac>,2
+CLCK: <status>
For <fac> with several supported
<class>es:
+CLCK=<fac>,2
+CLCK: <status>,<class1>
[<CR><LF>
+CLCK: <status>,<class2>
[…]]
OK
The Set command performs the
specified <mode> action on the
specified <fac>.
Read
+CLCK?
ERROR
Test
+CLCK=?
+CLCK: (list of supported <fac>s)
The Test command returns the list
of supported facilities.