at+MCELL=0,22
OK
MCC:460,MNC:0,LAC:9339,Cell ID:03600,BSIC:27,(P)BCCH
ARFCN:76,RxLev:56,RxDbm:-54,C1:30,C2:30,TxPower:5,RxAccMin:6,(PD)TCH
ARFCN:INVALID_ARFCN,Timeslot:0,MAIO:0,HSN:0,Timing
Advance:255,RxQualFull:6,RxQualSub:6
at+MCELL=0,23
OK
NCELL:1,MCC:460,MNC:0,LAC:9339,Cell ID:04361,BSIC:41,(P)BCCH
ARFCN:82,RxLev:32,RxDbm:-78,C1:17,C2:13
NCELL:2,MCC:460,MNC:0,LAC:9339,Cell ID:04362,BSIC:38,(P)BCCH
ARFCN:60,RxLev:9,RxDbm:-101,C1:-1,C2:-1
This command returns neighbor cell information. The command returns ARFCN, BSIC and RX level of
serving and adjacent cells. In case Module is registered, adjacent cells are from registered PLMN. In case
Module is in Emergency Mode, adjacent cells are physical neighbors. BSIC is displayed only in case SCH
(Synchronization Channel) is decoded.
The parameter <enable_TA> determines whether <TA> will be reported by +MCI command. <TA> is
defined for serving cell only. This value will be displayed only in Dedicated mode. The command output is
<Filter>dependent. In case the command output should be filtered to include just cells of a specific GSM
band (one or more) the filter parameter should be set accordingly. The filtering will apply to the neighbor's
cells only – the serving cell info will always be returned.
Using the set command without a parameter will return output according to the currently set <Filter>
value.