EasyManua.ls Logo

Fibocom G510 - 4.1.7 &F, Set to Factory Defined Configuration

Fibocom G510
243 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G5/G6-Family AT Commands User Manual Page
27
of
243
...
(profile data)
OK
or
+CME ERROR: <err>
Example:
AT&V
ACTIVE PROFILE
&C1, &D1, &K3, E1, Q0, V1, X0, S0:0, S3:13, S4:10, S5:8, +CRC: 0
STORED PROFILE 0:
&C1, &D2, &K3, E1, Q0, V1, X0, S0:0, S3:13, S4:10, S5:8, +CRC:0
OK
4.1.7 &F, Set to Factory Defined Configuration
This command restores the factory default configuration profile. The Module only supports one factory
default profile, 0.
Command
Syntax
Response/Action
Remarks
Set
AT&F<value>
OK
or:
+CMS ERROR: <err>
Read
AT&F?
<current profile number>
Test
The Test command for &F is not
defined by ITU, and therefore is not
supported by the Module. The
Module returns an error.
The following table shows the &F parameters.
<Parameter>
Description
<value>
0 Factory default configuration profile. This is the only value supported.

Table of Contents