10.1.2+MTSM, Temperature Sensor Measurement
This command measures the current temperature sensor value in Celsius degrees.
This temperature is taken from a internal thermostatically of Egold.
All the parameters are saved on the NVM, and used after power up.
All the parameter values should be 0 (zero) in first operation of the module.
Note: In case AT parameters are set and executed, and a reset or a power-cycle occurs, the G510-A20
continues with the execution of the AT command using the saved parameters, until the user changes the
settings.
Command
Syntax
Response/Action
Remarks
Set
+MTSM=<Report
>[,<Rate>][,<Low
>,<High>]
For <Report>=0
OK
For <Report>=1
+MTSM: <Temp>
OK
For <Report>=2 or 3
OK
+MTSM: <Temp>
+MTSM: <Temp>
or:
ERROR: <error code>
Read the temperature.
Read
+MTSM?
+MTSM=<Report>,<Rate>,<Low>,
<High>
OK
Read the setting
parameters.
Test
+MTSM=?
+MTSM: (range of
<Report>),(range of
<Rate>),(range of <Low>/<High>)
OK
The following table shows the +MTSM parameters.
<Parameter>
Description
<Temp>
-40 - 95; Temperature measurements in Celsius degrees.
<Report>
0; Deactivate unsolicited report.
1; Report once the current temperature.