2; Activate unsolicited report.
3; Activate unsolicited report only for out-off boundaries events.
<Rate>
1-255; Select the time interval in seconds between the unsolicited reports.
(Default value = 1 Second).
<Low>
-40 - 95; The lowest boundary level of the temperature value for unsolicited
report.
(Default value = 0 Celsius).
Setting corresponding <Low> and <High> temperature boundaries for
<Report>=3 only.
<High>
-40 - 95; The Highest boundary level of the temperature value for unsolicited
report.
(Default value = 0 Celsius).
Setting corresponding <Low> and <High> temperature boundaries for
<Report>=3 only.
Example:
AT+MTSM=? // Test the range of the parameters.
+MTSM: (0-3),(1-255),(-40-95)
OK
AT+MTSM=1 // Set to read for once the current temperature measurement.
+MTSM: 35 // Current temperature is +35 Celsius degree.
OK
AT+MTSM=2,5 // Set to unsolicited temperature reports to TE for every 5 seconds.
OK
+MTSM: -10 // Current temperature measure report -10 Celsius.
+MTSM: -5 // Unsolicited temperature report -5 Celsius after 5 seconds.
+MTSM: 7 / Unsolicited temperature measure report +7 Celsius after 10 seconds.
+MTSM: 20 // Unsolicited temperature measure report +20 Celsius after 15 seconds.
+MTSM: 50 // Unsolicited temperature measure report +50 Celsius after Nx5 seconds.
AT+MTSM=0 // Set to stop the unsolicited report.