54200
Users Manual
5-8
Additional for Fluke 54200 with VPS/PDC Option:
The displayed PDC test data, date, and time on Page 300, are identical to the contents of
the same PDC memory locations 1 to 9. When you have programmed the PDC memory lo-
cations 1 to 4, automatically the timer data are changed on Teletext Page 300 if the
instrument is in the Teletext TOP2 or FLOF2 mode. The locations 5
to 9 contain fixed
data, see Table
5-3
.
For programming PDC, see Page 5-25.
The operating instructions of your VCR shows you how to program the VCR using
PDC.
For PDC it is required to have a real time clock which is offered by 54200. In the
Teletext TOP2 and FLOF2 mode the real time clock of the instrument is used for
generating the Universal Date and Time (UDT) code in Data Packet 8/30 format 1.
Please refer to Page 5-20 how to program the real time clock.