Users Manual
6-40
Device Setting Queries
All device specific commands can also be sent as query, except the commands for
programmed Teletext, VPS, PDC data and WSS. The responses use the basic units Volts,
Hertz, dBc, minutes or seconds. In addition you can send following queries:
RF query
Query:
RF?
Response headers:
FREQ
Vision carrier frequency
LEVE
Carrier amplitude
LEVR
Level range of the carrier amplitude
Response example:
FREQ 203.25E+6;LEVE 0.01;LEVR L
System query
Query:
STAN?
Response headers:
COUN
Country
TVST
TV standard
GRPD
Group delay
RESC
Residual carrier
FRAM
SACAM Frame Identification
Response example:
COUN 49;TVST PALG;GRPD OFF;RESC L
Remark: FRAM is only sent if SECAM is on.