Function Reference
Wide Screen Signalling (WSS)
5
5-17
WSS Manual Mode
In the
WSS Manual
mode the user has the advantage to set the single WSS bits.
• Select the
Wide Screen Signalling
popup menu.
• Select the WSS
Manual
mode
• Press the
enter
softkey (F5).
The
WSS Editor
popup menu appears.
• Toggle the wanted WSS bits by using the
ç
,
è
, and
Toggle
softkeys (F1, F2, F3).
• Press the
enter
softkey (F5) to confirm your settings.
Figure 5-11. WSS Bits Manual Mode
The display shows the 14 bits of the WSS data group 1 to 4, beginning with bit 0 on the
left. Each bit can be set to 0 or 1. For detailed programming the WSS bits, see Table
5-7,
WSS Status Bits Transmission Scheme
.
Figure
5-11
shows an example with the following WSS settings:
Group 1 1110 16:9 pattern
Group 2 1000 Non-camera mode pattern
Group 3 100 Teletext on
Group 4 100 Stereo on
Remark:
The instrument does not check the consistency of the user programmed WSS data.