54200
Users Manual
7-4
Video and RF
Outputs
CVBS Video
Voltage (Vpp into 75
) 1 V (nominal setting)
Setting range 0 to 1.5 V
Tolerance of setting 10 mV or 5%, whichever is greater,
5 mV or 2%, whichever is greater, at reference temperature
Step size 1%,
10 mV for internal video
Resolution 10 mV
Impedance 75
Polarity Positive/ negative, selectable
Coupling DC
Luminance/chrominance
timing difference
40 ns
Connector VIDEO OUT, BNC front,
EURO AV OUT, EURO AV connector rear
Max. external voltage ±9 V
CVBS SYNC, LINE SYNC and FIELD Synchronization
Voltage (Vpp into 75
)2 V
Tolerance 0.3 V
Impedance 75
Polarity Negative
Coupling DC
Connector SYNC OUT: COMP, LINE; FIELD,
BNC rear
Max. external voltage ±4 V
EURO AV Control Voltages
Aspect Ratio Pin 8,
Automatically or Off
OFF 0 V to +2 V
Ratio 4:3 +9.5 V to +12 V
Ratio 16:9 +4.5 V to +7 V
Impedance 850