Brief Functional Test
Brief Functional Test
8
8-3
Brief Functional Test
Introduction
The information in the following paragraphs contains the functional test of the key
parameters of the Fluke 54200 TV Signal Generator.
If you want to check the specifications of the generator in detail, you can use the
Performance Test in the Service Manual, order number 4822 872 15185. For the
Performance Test, special TV-Test Equipment, for example, a video analyzer (Tektronix
VM700A) is necessary.
This Brief Functional Test may be used as an acceptance test upon receipt of the
instrument, as an indication that repair and/or adjustment is required, or as an functional
test after repair or adjustment of the instrument. This test describes a check of an
instrument with all options built-in. If an option is not built-in in the instrument under
test, please skip the corresponding steps.
When you have finished the Brief Functional Test or if you abort the test, you should
perform
RECALL 0
to set the instrument in a defined default status, see Chapter 6,
‘*RST Reset Command.’
Recommended Test Equipment
TV Receiver, Multi System with:
•
Analog stereo sound
•
NICAM-sound
•
Teletext
•
RGB & Y/C input,
for example, Philips 25PT 8302
TV Receiver, NTSC-System with:
•
BTSC-sound
•
Closed Caption,
for example, Magnavox P2783 C101 / Philips 27V505-00A
Oscilloscope with:
•
TV/Line trigger
for example, Fluke PM3382A/061