54200
Users Manual
7-12
Aging
2 ppm per year
Level -13 dBc for system B, G
-10 dBc for system D, I, K, K1, L, M, N
Tolerance 2 dB at reference temperature
Setting range -5 dBc to -15 dBc
Tolerance 2 dB at reference temperature
Resolution 1 dB
Modulation
Frequency 0.5, 1.0, 3.0 kHz:
for system B, D, G, I, K, K1, L (S1 Modulation) or off
0.3, 1.0, 3.0 kHz:
for system M and N (S1 Modulation) or off
0.5, 1.0, 3.0 kHz: (S3 Modulation) or as NICAM
for system NICAM B/G, NICAM DK, DC, I, L or off
Type FM for system B, D, G, I, K, K1, M, N
AM for system L
Deviation 27 kHz for system B, D, G, I, K, K1 (pre-emphasis off),
13.5 kHz for system M, N (pre-emphasis off)
Tolerance 5%
Pre-emphasis (FM) 50
µ
s for system B, D, G, I, K, K1 or off
75
µ
s for system M, N or off
Modulation depth 54% for system L
Tolerance (absolute) 5%
Stereo /Dual
Sound Carrier 1
Data As Mono
Modulation matrix:
Stereo (L+R)/2
Dual CH1 (S1 Modulation)
Sound Carrier 2
Frequency 5.7421875 MHz for system B, G
6.2578125 MHz for system D, K (A2)
4.724 MHz for system Mk
Tolerance 3 ppm for +5 to +45
°
C
1 ppm at reference temperature
Aging
2 ppm per year
Level -20 dBc
Tolerance 3 dB at reference temperature