EasyManua.ls Logo

Fluke 54200 - Sound

Fluke 54200
386 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control
Remote Control Commands
6
6-31
Sound
Sound System
Header:
SNDSY
STEM
Data element:
AML | FMM
ONO
| FMG
ERMANY
| FMA2 | FMK
OREA
| B
TSC
|
NICAMB | NICAMDK | NICAMDC | NICAMG | NICAMI | NICAML
Example:
SNDSYSTEM FMGERMANY
or
SNDSY FMG
selects the German sound system.
Sound Mode
Header:
SNDM
ODE
Data element:
M
ONO
| D
UAL
| S
TEREO
| TEST1 | TEST2 | TEST3
Remark: If NICAM is on, this command selects the digital sound mode, the
analog sound is always set to MONO.
Example:
SNDMOD DUAL
or
SNDM D
selects the DUAL sound mode.
Sound Source
Header:
SNDSO
URCE
Data element:
I
NTERN
| E
XTERN
| S
CART
| C
INCH
| M
TS
Remark: If NICAM is on, this command selects the analog sound source; the
digital sound is always internal.
MTS is for 4.5 MHz systems only, for external BTSC.
Example:
SNDSOURCE INTERN
or
SNDSO I
selects the internal sound source.

Table of Contents