EasyManua.ls Logo

Fluke 54200 - Page 235

Fluke 54200
386 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control
Remote Control Commands
6
6-27
Mnemonic Pattern Description
DIGI_ADC1
Digital Scan, ADC Check 1
DIGI_ADC2
Digital Scan, ADC Check 2
DIGI_M
OVE
Moving block
DIGI_SCAN1_S
Progressive Scan Check 1, still
DIGI_SCAN1_M
Progressive Scan Check 1, moving
DIGI_SCAN2_S
Progressive Scan Check 2, still
DIGI_SCAN2_M
Progressive Scan Check 2, moving
DIGI_SCAN3_S
Progressive Scan Check 3, still
DIGI_SCAN3_M
Progressive Scan Check 3, moving
CTA_S
MALL
Color Temperature Adjustment, size 1
5)
CTA_M
EDIUM
Color Temperature Adjustment, size 2
5)
CTA_L
ARGE
Color Temperature Adjustment, size 3
5)
EH
TTEST
EHT test pattern
I
RS
17
Pattern of Insertion-Reference Signal Line 17
O
FF
Black pattern (black screen)
1. Black or white cross, depending on background.
2. 0% and 5% for 625 line systems only.
7.5% for 525 line systems only.
If you select 0% or 5% in a 625 line system and switch to a 525 line system, the instrument sets
7.5% (IRE), that is the lowest level in the 525 line system.
Switching back to a 625 line system sets the level to 0%.
3. The table shows the primary color signal levels for the 625 line systems. For the 525 line systems the
minimum values are set to 7.5% instead of 0%.
4. Purity part of the split field color set by the purity command, e.g., PAT COL_SP1;PAT PUR_R.
5. The luminance value can be set by the command CTABORDER for the border and CTACENTER for
the center.
Remark: For combinations send separate commands with the different patterns.
To reset all patterns send
PATTERN
OFF
.
A string is executed from left to right.
If a pattern is selected that does not match with the previously selected,
the previously selected is switched off.
The device cannot accept more than 16 pattern commands in one string.
PAT CHE; PAT CI; PAT VCR_PAT1
; switches VCR1 and Circle
on, the checkerboard is ignored because is does not match the VCR1
pattern.
For legal pattern combinations see Chapter 4.
Example:
PATTERN OFF;PATTERN CI;PATTERN PUR_YELLOW;
PATTERN COL_SP_100;
or
PAT O;PAT CI;PAT PUR_Y;PAT COL_SP_100
clears first all patterns and then sets circle, purity yellow, and split field
colorbar.

Table of Contents