Remote Control
Remote Control Commands
6
6-29
White level for the border of the Color Temperature Adjustment pattern
Header:
CTAB
ORDER
Data element:
NRf
Suffix:
[
PCT
| IRE
]
Remark:
NRf
for 625 line systems: 0, 50, or 100%.
NRf
for 525 line systems: 7.5, 53.75, or 100 IRE.
Example:
CTABORDER 100PCT
or
CTAB 100
sets the luminance for the CTA border to 100% for 625 line systems.
White level for the center of the Color Temperature Adjustment pattern
Header:
CTAC
ENTER
Data element:
NRf
Suffix:
[
PCT
| IRE
]
Remark:
NRf
for 625 line systems:
Range from 0%, 5%, 15% to 100% in 5% steps.
NRf
for 525 line systems:
Range from 7.5, 15, 20 to 100 IRE in 5 IRE steps.
See also White Pattern, Page 6-26.
Example:
CATCENTER 20PCT
or
CTAC 20
sets the luminance for the center of the CTA pattern to 20%.
Aspect Ratio
Header:
ASPR
ATIO
Data element:
R16_9 | R4_3
Example:
ASPRATIO R16_9
or
ASPR R16_9
sets the Aspect Ratio to 16:9.