Remote Control
Remote Control Commands
6
6-37
VPS
Header:
VPSN
UMBER
Data element:
NRf
Remark:
NRf
is a number from 0 to 9.
0 = off,
1 to 9 are the VPS data sets.
This command switches VPS on or off and selects the data set.
For VPS, Teletext must be switched on.
Example:
VPNSNUMBER
or
VPSN 3
recalls the VPS data set 3.
Programming of PDC/VPS
Header:
PDCD
ATA |
VPSD
ATA
Data element:
NR1
Remark:
NR1
is the set number, a string with the complete PDC or VPS data,
and a string with the program title.
The data sets 1 to 4 are programmable.
The format of the first string is:
DD.MM, HH:MM, Country, Network, PTY, Reserved bits, Flags.
The ranges are:
0 to 31 for day and hour,
0 to 15 for month and flags,
0 to 63 for minutes,
0 to 255 for country, network and program type (PTY),
0 to 3 for reserved bits,
0 to 15 for the flags (PDC only).
For the flags value the MSB bit is the PRF, the MSB -1 is the LUF bit,
and the two LSB bits are the LCI bits.
The separators in the string may be a full stop, colon, comma, or a
space. The second string may contain any printable ASCII character
except ' " ' or ' ' '. Its length is at most 20 characters.
Example:
PDCD 3,"27.12,12:00,123,23,255,0,0","Gentlemen Gangsters"
VPSD 3,"27.12,12:00,123,23,255,0","Gentlemen Gangsters"
writes the PDC/VPS data for date (27.12), time (12:00), country (123),
Network (23), PTY (255), reserved bits (0), flags for PDC (0), and the
program title as set number 3 into the memory.